Validity and reliability test of an Electric Knee Height Measuring Device (EKHMD) predicting body height and nutritional status

Authors

  • Alfian Abdul Rajab STIKES Banyuwangi, Banyuwangi, Indonesia, Indonesia
  • Fista Utami Universitas Negeri Surabaya, Surabaya, Indonesia, Indonesia

DOI:

https://doi.org/10.34011/jmp2k.v36i1.4228

Keywords:

EKHMD, estimated height, immobilization, knee height, nutritional status

Abstract

Background: Direct height measurement is often difficult in immobilized patients. Knee height measurement becomes an alternative, thus encouraging the development of an electronic knee height measuring device (EKHMD).

Objective: The aim of this study was to determine the validity and reliability of the EKHMD in estimating knee height, height, and nutritional status.

Methods:  This study used a quantitative approach with 30 healthy adults (15 men, 15 women) through purposive sampling. Anthropometric measurements used the EKHMD and a microtoise as standards. Validity was assessed using Pearson or Spearman correlation tests, agreement or accuracy using Bland–Altman plot analysis, and reliability using Cronbach-Alpha.

Results: The results of the validity test showed that knee height measurements (r = 0.929), estimated height (r = 0.863 (sitting), r = 0.869 (lying down), and nutritional status (r = 0.952 (sitting), r = 0.970 (lying down) with significance for all variables (p = 0.00) which means that EKHMD correlated strongly with microtoise measurements (p < 0.05). Accuracy analysis using Bland–Altman measurements was in the range of Upper LoA and Lower LoA knee height (2.13 – (-1.43 cm)), estimated height (7.89 – (-9.05) cm (sitting) 0.049 (-0.029) cm (lying down)), and nutritional status (2.35 – (-2.01) (sitting), 0.06 – (-0.023) (lying down)) and Cronbach’s Alpha showed high reliability (p > 0.60), knee height (p=0.61), estimated height ((p=0.936 (Sitting), p=0.928 (Lying)), and nutritional status (p=0.983 (Sitting), p=0.984 (Lying)).

Conclusion: Thus, EKHMD can be considered as a tool to measure estimated height and nutritional status but still needs to be developed further.

References

[1] A. Widiyawati, Y. Yuanta, and A. D. Sari, “Modifikasi Alat Ukur Tinggi Lutut untuk Pasien Bedrest,” Arter. J. Ilmu Kesehat., vol. 1, no. 4, pp. 340–348, 2020, doi: 10.37148/arteri.v1i4.120.

[2] W. S. N. Azkiyah, D. Handayani, and others, “Validitas Estimasi Tinggi Badan berdasarkan Tinggi Lutut pada Lansia di Kota Malang (Validity of Height Estimation based on Knee Height in the Elderly in Malang),” Indones. J. Hum. Nutr., vol. 3, no. 2, pp. 93–104, 2016, doi: 10.21776/ub.ijhn.2016.003.02.5.

[3] T. U. Kusuma and A. Rosidi, “Reliabilitas Kaliper Tinggi Lutut dalam Penentuan Tinggi Badan,” J. Heal. Stud., vol. 2, no. 1, pp. 96–102, 2018, doi: 10.31101/jhes.437.

[4] L. Rumbo-Rodr’iguez, M. Sánchez-SanSegundo, R. Ferrer-Cascales, N. Garc’ia-D’Urso, J. A. Hurtado-Sánchez, and A. Zaragoza-Mart’i, “Comparison of body scanner and manual anthropometric measurements of body shape: a systematic review,” Int. J. Environ. Res. Public Health, vol. 18, no. 12, p. 6213, 2021, doi: https://doi.org/10.3390/ijerph18126213.

[5] E. Ulfameytalia Dewi, N. A. Primasari, W. Sugiarti, A. H. Widagdo, P. Sarjana, and S. Guna, “Uji Validitas Reliabilitas Instrumen Analisis Stunting Dengan Pendekatan Teori Leininger Dan Family Centered Nursing,” Ilmu Kesehat. Mandira Cendikia, vol. 3, no. 8, pp. 384–394, 2024, doi: https://doi.org/10.70570/jikmc.v4i12.

[6] C. D. A. A. Istri and R. Fadila, “Uji validitas dan reliabilitas kuesioner pengetahuan masyarakat tentang program JKN,” J. Kesehat. Qamarul Huda, vol. 11, no. 1, pp. 307–315, 2023, doi: https://doi.org/10.37824/jkqh.v11i1.2023.462.

[7] S. J. Ulijaszek and D. A. Kerr, “Review article Anthropometric measurement error and the assessment of nutritional status,” vol. 82, no. 3, pp. 165–177, 1999, doi: https://doi.org/10.1017/S0007114599001348.

[8] F. M. Silva and L. Figueira, “Estimated height from knee height or ulna length and self-reported height are no substitute for actual height in inpatients,” Nutrition, vol. 33, no. 1, pp. 52–56, 2017, doi: https://doi.org/10.1016/j.nut.2016.08.011.

[9] W. S. Nur Azkiyah, D. Handayani, and H. -, “Validitas Estimasi Tinggi Badan berdasarkan Tinggi Lutut pada Lansia di Kota Malang (Validity of Height Estimation based on Knee Height in the Elderly in Malang),” Indones. J. Hum. Nutr., vol. 3, no. 2, pp. 93–104, 2016, doi: 10.21776/ub.ijhn.2016.003.02.5.

[10] R. Karnia, “Importance of Reliability and Validity in Research,” Psychol. Behav. Sci., vol. 13, no. 6, pp. 137–141, 2024, doi: 10.13140/RG.2.2.30985.45921.

[11] F. D. P. Anggraini, H. K. Rahayu, R. Inayati, and S. Bongga, “Uji Validitas Dan Reliabilitas Instrumen Literasi Malaria,” J. Kesehat. Tambusai, vol. 6, no. 1, pp. 2276–2284, 2025, doi: https://doi.org/10.31004/jkt.v6i1.42373.

[12] N. Nelsi, A. Afriani, and U. W. Abidin, “Validasi Pengukuran Antropometri Berat Badan (BB) dan Tinggi Badan (TB) oleh Kader Posyandu di Desa Balabatu Kecamatan Tandukkalua Kabupaten Mamasa,” J. Peqguruang, vol. 2, no. 1, pp. 269–273, 2020, doi: http://dx.doi.org/10.35329/jp.v2i1.1580.

[13] M. Vukotic, “Body Height and its Estimation Utilizing Hand Length Measurements in Montenegrin: National Survey,” Int. J. Morphol., vol. 40, no. 2, pp. 396–400, 2022, doi: http://dx.doi.org/10.4067/S0717-95022022000200396.

[14] A. D. Wahyani, I. P. Ana, and Y. D. Rahmawati, “Perbedaan tinggi badan aktual dengan tinggi badan berdasarkan tinggi lutut dan panjang ulna pada lansia di Posbindu Desa Cikuya,” J. Ilm. Gizi Kesehat., vol. 4, no. 02, pp. 14–19, 2023, doi: https://doi.org/10.46772/jigk.v4i02.1031.

[15] M. Ludya, Y. Herlambang, and D. Yunidar, “Produk alat ukur tinggi dan berat badan pendeteksi stunting dengan fitur hiburan untuk anak usia 2-5 tahun,” Prod. J. Desain Prod. (Pengetahuan Dan Peranc. Produk), vol. 6, no. 1, pp. 51–62, 2023, doi: 10.24821/productum.v6i1.7685.

[16] M. A. Bakri et al., “Pembuatan Alat Pengukur Tinggi Badan Otomatis Berbasis Arduino,” DEVOSI, vol. 3, no. 1, pp. 29–36, 2022, doi: 10.33558/devosi.v3i1.3184.

[17] S. Susetyowati, H. Winarti, A. Roselani, S. Handayani, N. D. G. Sanubari, and A. S. Sholikhati, “Utilization of Mini Nutrition Assessment-Short Form to Identify Nutritional Status of Hospitalized Elderly Patients at Dr Sardjito General Hospital, Yogyakarta,” Amerta Nutr., vol. 8, no. 2, pp. 263–268, 2024, doi: 10.20473/amnt.v8i2.2024.263-268.

[18] E. Speranza et al., “Nutritional screening and anthropometry in patients admitted from the Emergency Department,” Front. Nutr., vol. 9, no. 1, p. 816167, 2022, doi: 10.3389/fnut.2022.816167.

[19] S. Sugiono, N. Noerdjanah, and A. Wahyu, “Uji validitas dan reliabilitas alat ukur SG posture evaluation,” J. Keterapian Fis., vol. 5, no. 1, pp. 55–61, 2020, doi: https://doi.org/10.37341/jkf.v5i1.167.

[20] R. Rusdiarti, “Analisis pengukuran ketepatan antropometri tinggi badan balita pada pelatihan kader posyandu di Panduman Kecamatan Jelbuk,” Heal. Inf. J. Penelit., vol. 11, no. 2, pp. 173–181, 2019, doi: 10.36990/hijp.v11i2.141.

[21] F. Susanto, S. Mintoro, A. Kohar, and N. Nurbaiti, “Sistem Pengukur Tinggi Tubuh OtomatisMenggunakan Arduino Uno R3 Dan Sensor Ultrasonik Hc-Sr04,” J. Komputasi, vol. 12, no. 2, pp. 134–142, 2024, doi: 10.23960/komputasi.v12i2.262.

Downloads

Published

2026-03-31

How to Cite

Rajab, A. A., & Utami, F. (2026). Validity and reliability test of an Electric Knee Height Measuring Device (EKHMD) predicting body height and nutritional status. Media Penelitian Dan Pengembangan Kesehatan, 36(1), 306–316. https://doi.org/10.34011/jmp2k.v36i1.4228

Citation Check

Similar Articles

<< < 1 2 3 4 5 6 > >> 

You may also start an advanced similarity search for this article.